BMS 48V; 60A; 16 cell

BMS 48V; 60A; 16 cell
Details

Voltage:

  • Charging voltage: DC 57.6 V; 3.6 V / cell
  • Balance voltage for single cell: 3.60 ± 0.025 V

Current:

  • Balance current for single cell: 72 ± 10 mA
  • Current consumption / cell: =< 20 μA
  • Maximal continous charging current: 60 A
  • Maximal continous discharging current: 60 A

Over charge protection:

  • Over charge detection voltage: 3.90 ± 0.025 V
  • Over charge detection delay time: 0.7 S - 1.3 S
  • Over charge release voltage: -

Over discharge protection:

  • Over discharge detection voltage: 2.00 ± 0.062 V
  • Over discharge detection delay time: 14 mS - 26 mS
  • Over discharge release voltage: 2.50 ± 0.1 V

Over current protection:

  • Over current detection voltage: 0.1 ± 0.020 V
  • Over current detection current: 200 ± 30 A
  • Detection delay time: 7.2 mS - 11 mS
  • Release condition: Cut load

Short protection:

  • Detection condition: Exterior short circuit
  • Detection delay time: 200 - 500 uS
  • Release condition: Charge release

Resistance:

  • Protection circuitry (MOSPET): =< 20 mΩ

Temperature:

  • Operating temperature range: -40 ~ +85 °C
  • Storage temperature range: -40 ~ +125 °C

Profile

Wiring 1. Wiring 2.

Ingredients: 2× BMS-460-8

Info
Article No.
BMS_48V_60A_c16
Opinions

Be the first to review this product!